Raft foundation basics

Blog Post
Raft foundation basics - picture of a raft foundation

A raft foundation is a reinforced concrete slab under the whole of a building or extension, 'floating' on the ground as a raft floats on water. This type of foundation spreads the load of the building over a larger area than other foundations, lowering the pressure on the ground.

This is an alternative if you can't use a traditional strip or trench fill foundations.

But it's important to note that raft foundations aren't suitable in all cases and usually need to be designed by a structural engineer.

Here are important considerations if you're thinking about using a raft foundation:

  • The raft design usually has an 'edge beam' formed by a cage of steel reinforcement, which will need to be carefully assembled on site. Internal stiffening beams are sometimes needed too. These beams transfer the building loads through the rest of the slab and then evenly over the ground.
  • A site investigation is usually needed for the engineer to understand what the ground is like. Very poor ground may mean you need a different solution such as piles.
  • The raft design will normally need a hardcore sub-base to level the ground. This stone should be mechanically compacted.
  • You must ensure steel reinforcement is lapped at least 450mm (for both mesh and mild steel bars) and provided with 40mm concrete cover. 'Treading in' the reinforcement during the concrete pour isn't a suitable means of placing reinforcement - use the special 'chairs' or 'soldiers' to support the mesh.
  • The edge of the raft must be carefully detailed for the damp course and membrane position, which may need a 'step' forming in the concrete at the raft edge.
  • Insulation is usually placed over the top of the raft - take care to avoid cold bridging at the junctions with external walls.

Important! A structural engineer designing a raft foundation may not be fully aware of damp coursing, cold bridging or land contamination issues. Ensure that the building designer considers these details before constructing the raft - once the concrete is poured it may be difficult to overcome.

If in doubt, speak to your local authority building control surveyor. Use our free post code search tool to find contacts for your local LABC team.

Banner image courtesy of Surtees Groundworks, Berkshire.

Find this page useful? Read more about working with foundations


Please Note: Every care was taken to ensure the information was correct at the time of publication. Any written guidance provided does not replace the user’s professional judgement. It is the responsibility of the dutyholder or person carrying out the work to ensure compliance with relevant building regulations or applicable technical standards.

This article was reviewed on 9 August 2023.

Comments

Great stuffs

Submitted 3 years ago

I was searching the web and this article really clears my all doubts about the raft foundation. Thanks mate.

LABC response

Submitted 3 years ago

Hi,

Thank you for your comment, glad you found it helpful!

Best,
LABC team

embedments in raft foundation

Submitted 2 years 4 months ago

is it possible to embedded a sewage pipes with a diameter equal to 4 inches inside a raft foundation with 16 inches thickness?
is there any code allow or restrict this method?

LABC response

Submitted 2 years 4 months ago

Hi,

Thankyou for your enquiry, a raft foundation is a specialist type of structure and as such we would expect a structural engineer to design the reinforcement, cover and to consider the position of drains in relation to the external loadbearing walls, as such you would need to consider the protection and level of reinforcement ( rebar) around services such as drains and the like. It would not be possible to give a definitive answer, albeit drain runs can be incorporated, therefore we would advise that you should contact your structural engineer for advice.

Best,
LABC team

Raft sunk

Submitted 1 year 9 months ago

The concrete under our conservatory has sunk a little.. is there a process to level it up?

In reply to by Rob (heb ei wirio)

LABC response

Submitted 1 year 9 months ago

Hi,

Unfortunately, LABC are unable to assist you with your issue and building regulations do not cover ongoing maintenance to properties. We recommend you contact a structural engineer or building surveyor to advise you because you could have an underlying problem that requires attention before you carry out a repair.

Best,
LABC team

B.sc in Civil Engineering

Submitted 1 year 5 months ago

Raft Foundation design is very good solution for soft soil.

Helical Piling in Combination with a Reinforced Concrete Raft

Submitted 1 year 3 months ago

We are current Piling on an Large extension with is near a river , the ground has hardly any resistance, zero chalk , mainly loose stone ans black soil the engineer has specified a 200mm thick reinforced A383 mesh top and bottom with links all around perimeter and our pile layout

Ychwanegu sylw newydd

This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

Sign up to the building bulletin newsletter

Over 48,000 construction professionals have already signed up for the LABC Building Bulletin.



Join them and receive useful tips, practical technical information and industry news by email once every 6 weeks.



Subscribe to the Building Bulletin