External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Pitched Roof Gable
400mm insulation (0.044W/mK) at Ceiling Level
Ventilated Loft
This LABC Registered Construction Detail is…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Partial Fill Insulation
Window Sill
This LABC Registered Construction Detail is only valid for use with building work intended to follow the…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK
Full Fill Insulation
Pitched Roof Gable
150mm insulation (0.022W/Mk) between rafters
50mm insulation (0.022W/Mk) beneath rafters
This LABC Registered…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Normal Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Independent Concrete Lintel
Soffit Insulation
This LABC Registered Construction Detail is only valid for use with building work intended…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf
Ultra Lightweight Concrete Block Inner Leaf λ ≤ 0.28 W/mK
Partial Fill Insulation
Window Jamb
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
150mm Beam and Aircrete Block Infill
150mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Beam and Block Floor
Lightweight Floor Block
150mm Insulation Below Screed (0.022W/mK)
This LABC Registered Construction Detail…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Independent Lintel
Proprietary PVC-U Cavity Closer
This LABC Registered Construction Detail is only valid for use with…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Partial Fill Insulation
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
150mm Beam and Aircrete Block Infill
150mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered…