External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Partial Fill Insulation
Concrete Separating Floor Between Dwellings
150mm Precast Concrete Floor Plank
This LABC Registered Construction…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
Concrete Separating Floor Between Dwellings
150mm Precast Concrete Floor Plank
This LABC Registered Construction Detail…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Beam and Block Floor
Dense Floor Block
150mm Insulation Below Screed (0.022W/mK)
This LABC Registered Construction Detail is…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Steel Lintel, Open Back
(No continuous base plate)
This LABC Registered Construction Detail is only valid for use with…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Pitched Roof Gable
150mm insulation (0.022W/Mk) between rafters
50mm insulation (0.022W/Mk) beneath rafters
This LABC Registered Construction…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Partial Fill Insulation
Inverted Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Inverted Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK
Partial Fill Insulation
Normal Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Partial Fill Insulation
In Situ Ground Bearing Concrete Floor
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
In Situ Ground Bearing Concrete Floor
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is…