Search
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤ 1.33 W/mK
Full Fill Insulation
Independent Concrete Lintel
Soffit Insulation
This LABC Registered Construction Detail is only valid for use with building work intended to…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK
Partial Fill Insulation
Window Jamb
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Concrete Separating Floor Between Dwellings
150mm Precast Concrete Floor Plank
This LABC Registered Construction Detail…
More than 850 leading construction industry figures attended the LABC Building Excellence Awards at the Westminster Park Plaza Hotel to celebrate best practice, quality, and exemplary standards in construction.
The LABC Building Excellence Awards focus on professional skills and competence, as…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Partial Fill Insulation
Concrete Separating Floor Between Dwellings
150mm Precast Concrete Floor Plank
This LABC Registered Construction…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/Mk
Partial Fill Insulation
Beam and Block Floor
Dense Floor Block
150mm Insulation Below Screed (0.022W/mK)
This LABC Registered Construction Detail is…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Independent Lintel
Proprietary PVC-U Cavity Closer
This LABC Registered Construction Detail is only valid for use with…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Pitched Roof Gable
150mm insulation (0.022W/Mk) between rafters
50mm insulation (0.022W/Mk) beneath rafters
This LABC Registered…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Beam and Block Floor
Dense Floor Block
150mm Insulation Below Screed (0.022W/Mk)
This LABC Registered Construction Detail is only valid for use with building…
Build Up
Party Masonry Cavity Wall
Separating Wall and Roof
2 x Leaves Dense Blockwork Party (Separating) Wall
Cavity fully filled with insulation
150mm insulation (λ = 0.044W/mK) between the rafters
50mm (λ =0.022W/mK) below the rafters
This LABC Registered…