Pressure differential systems are widely accepted to be the safest way of controlling smoke in buildings, but have become less frequently specified because of the associated difficulties in design, commissioning, and upkeep.
The fundamental principle of pressurisation systems is that by…
The first thing that springs to mind when you look at The Dairy in the Yorkshire Dales might not be that it's a holiday cottage suitable for guests with mobility, hearing and visual impairments (although it is). What you might well notice instead is that it's a well designed…
R L Davies & Son was awarded the title of Best Partnership with a Local Authority Building Control Team at the Grand Finals of the LABC Building Excellence Awards – one of the most recognised events on the building industry’s calendar.A panel of industry experts judged a list of the…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60W/mK
Partial Fill Insulation
Pitched Roof Eaves
400mm insulation (0.044W/mK) at Ceiling Level
Ventilated Loft
This LABC Registered Construction Detail…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Inverted Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Independent Lintel
Proprietary PVC-U Cavity Closer
This LABC Registered Construction Detail is only valid for use with…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK
Beam and Block Floor
Lightweight Floor Block
100mm Insulation Below Screed (0.022W/Mk)
This LABC Registered Construction Detail is only valid for use…
Build Up
Masonry Party Wall
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
Ground Bearing Concrete Floor
Insulation Below Floor Slab
This LABC Registered Construction Detail is only valid for use with…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Partial Fill Insulation
Pitched Roof Eaves
150mm insulation (0.044W/mK) between rafters
50mm insulation (0.022W/mK) beneath rafters
Unventilated Rafter Void…