Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Beam and Aircrete Block Infill
100mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered Construction Detail is only valid for…
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.15 W/mK)
Render & Insulation (λ = 0.022 W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England
Approved…
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ ≤ 0.15 W/mK)
Render & Insulation (λ = 0.038 W/mK)
Pitched Roof Gable
400mm insulation quilt (0.044W/mK) at Ceiling Level
This LABC Registered Construction Detail is only valid for use with building…
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.038 W/mK)
In Situ Ground Bearing Concrete Floor
150mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with…
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.022 W/mK)
Pitched Roof Eaves (minimum pitch 40°)
400mm insulation quilt (0.044W/mK) at Ceiling Level
This LABC Registered Construction Detail is only valid for…
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.15 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Beam and Aircrete Block Infill
100mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered Construction Detail is only valid for…
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.19 W/mK)
Render & Insulation (λ = 0.022 W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England
Approved…
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ ≤ 0.19 W/mK)
Render & Insulation (λ = 0.038 W/mK)
Pitched Roof Gable
400mm insulation quilt (0.044W/mK) at Ceiling Level
This LABC Registered Construction Detail is only valid for use with building…
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.15 W/mK)
Render & Insulation (λ = 0.038 W/mK)
In Situ Ground Bearing Concrete Floor
150mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with…
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.15 W/mK)
Render & Insulation (λ = 0.022 W/mK)
Pitched Roof Eaves (minimum pitch 40°)
400mm insulation quilt (0.044W/mK) at Ceiling Level