Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Partial Fill Insulation
Pitched Roof Eaves
150mm insulation (0.044W/mK) between rafters
50mm insulation (0.022W/mK) beneath rafters
Unventilated…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Pitched Roof Eaves
400mm insulation (0.044W/mK) at Ceiling Level
Ventilated Loft
This LABC Registered Construction Detail is…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
150mm Beam and Aircrete Block Infill
150mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered Construction…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK Inner Leaf
Full Fill Insulation
2 x Lightweight Blockwork Leaves to Party (Separating) Wall
This LABC Registered Construction Detail is only valid for…
More than 850 leading construction industry figures attended the LABC Building Excellence Awards at the Westminster Park Plaza Hotel to celebrate best practice, quality, and exemplary standards in construction.
The LABC Building Excellence Awards focus on professional skills and competence, as…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Partial Fill Insulation
Window Sill
This LABC Registered Construction Detail is only valid for use with building work intended to follow the…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Beam and Block Floor
Lightweight Floor Block
100mm Insulation Below Screed (0.022W/Mk)
This LABC Registered Construction Detail is only valid for use with…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Normal Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Partial Fill Insulation
150mm Cast In-Situ Suspended Slab
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only…
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Beam and Block Floor
Lightweight Floor Block
100mm Insulation Below Screed (0.022W/mK)
This LABC Registered Construction Detail…