Does my new outbuilding need building regulations approval?
With the increase in people working from home during the pandemic, it seems a useful time to revisit the topic of building regulations and small detached buildings, especially those that are to be constructed in domestic settings as home offices, workshops and other uses.
As a rule, the construction of any new building is likely to be work that is controlled under the building regulations. However, there might be cases where some small, detached buildings can be treated as exempt from them. Previous LABC articles have touched on exempt or garden buildings, but here we’ll discuss small detached buildings in a little more depth.
Under the building regulations the erection of a building is treated as controlled building work – to which the building regulations must be applied and for which a notice must be given to the local authority before the work begins.
However, building regulation 9 allows some exceptions. These exceptions – or exemptions – can be found in Schedule 2 of the regulations.
The circumstances that permit three types of small, detached buildings to be exempt from the building regulations can be found in Class 6 of the Schedule (one of these is an air-raid shelter!).
This article focuses only on the following Classes of exempt small, detached buildings:
- Those with a floor area not exceeding 30m2; and
- Those with a floor area not exceeding 15m2
To be exempt from the regulations they must have the features listed below and they must not contain any sleeping accommodation (no beds in sheds).
Small, detached buildings less than or equal to 30m2
These must be single storey – a roof mezzanine or loft floor would not be permitted, and:
- The internal floor area must not be greater than 30m2 (for example 3m x 10m, or 5m x 6m), and
- The building must be constructed substantially of non-combustible material unless it is 1m or more away from any boundary.
These types of buildings are typically used as garages, workshops, home offices, garden rooms, saunas, solariums, indoor pools.
The boundary measurement rule is important as features such as fascias, soffits, guttering, rainwater pipes - anything that is part of and protrudes from the building - can be counted as being a point from which the closeness to the boundary can be measured. If any part of the building is between 0m to 0.999m then the materials that can be used for construction must be controlled.
In the case of a building closer than 1m to the boundary – to retain the exemption status – materials must be, in the main, non-combustible. That means they should be, for example, walls of brick, block, concrete panel, steel frame with metal cladding etc, and roofs of slate, clay or concrete tiles, or metal cladding.
If the building is 1m or more away from the boundary there are no restrictions on the type of materials that can be used.
Small, detached buildings less than or equal to 15m2
These are not limited to being single storey.
- The internal floor area must not be more than 15m2 (for example 3m x 5m, or 2-storeys of 7.5m2 each).
- There are no restrictions in relation to the closeness to the boundary, or the type of materials that must be used.
These smaller buildings can be constructed anywhere within the boundaries of the site (in the garden of a house, for example) and can be constructed from any material – for example it can be a wooden shed, gazebo, sauna, log-cabin, or fabric tent, or plastic playhouse etc.
It's important to know that the 'floor area' of the building means the aggregate area of every floor in the building, calculated by reference to the finished internal faces of the walls enclosing the area, or if at any point where there is no wall, by reference to the outermost edge of the floor. For example, in the case of a garage, if part of one wall is made up of a garage door, the measurement would be to the outside edge of the floor slab.
If the physical features or use do not fit with the rules for exempt status, this does not mean that the building can't be built, it just means that the work is controlled and must be notified to the council under the building regulations, and that a Full Plans or Building Notice application must be made, and the work must be inspected. (Visit the LABC Front Door website for information on how to apply for building regulations approval.)
Queries can also be discussed with your local authority building control team before you make an application - you can find their direct contact details using the LABC postcode search above.
If the detached building can be treated as exempt then other features can be classed as being exempt too – such as the provision of any toilets, showers, boilers or wood-burning stoves etc. inside the building, so long as these features do not materially change the status of the exemption.
To clarify how this work is controlled:
- The installation of any electrics where the electricity is from a source shared with or located inside a dwelling, in which case the installation must comply with Part P of the regulations and is notifiable work through a competent persons scheme.
- The installation of cold or hot water supplies from a source shared with or located inside any building other than a building or extension of a kind also described in Schedule 2, in which case the work must comply with Parts G1 – Cold water supplies and G3(2) & (3) Hot water storage systems of the building regulations - and is notifiable work.
- The extension of any existing drainage system to serve the exempt detached building, in which case the extended drainage must comply with Parts H1 – Foul drains; H2 – Wastewater treatment and cesspools; H3 – Rainwater drainage, where applicable however the drainage is part of the exemption and so doesn't have to be notified to the local authority.
- Whether a building can be treated as fully exempt from the building regulations or not, there are other matters that must also be considered and/or addressed before any work begins.
- Will the building require planning permission? (External link to the LABC Front Door website for further information.)
- Will a building over agreement (BOA) be required from the sewer authority – in the case of the building being constructed on or close to a public sewer?
- Will permission be required from the gas, electricity, or water authorities for building over or close to any pipes or cables?
Ignoring the above, regardless of building regulations, could result in a fine and/or the building being removed. Similarly, exemption from building regulations does not mean that the building should be unsafe and advice from a qualified and competent construction professional should always be obtained before embarking on such a project, to ensure the building is both safe and compliant. (Read the Front Door advice on choosing and working with a builder.)
Finally, where an existing exempt building is added to, by an extension, and the floor area increases to a point that the building is no longer exempt, this would be treated as a material change of use and the building regulations would apply to both the extended part and the existing building, and the work would be controlled and notifiable.
Further information
Building Regulations Part H (England): Drainage and Waste Disposal
Building Regulations Part H (Wales): Drainage and Waste Disposal
Please Note: Every care was taken to ensure the information was correct at the time of publication. Any written guidance provided does not replace the user’s professional judgement. It is the responsibility of the dutyholder or person carrying out the work to ensure compliance with relevant building regulations or applicable technical standards.
This article was reviewed and updated on 10 August 2023
Sign up to the building bulletin newsletter
Over 48,000 construction professionals have already signed up for the LABC Building Bulletin.
Join them and receive useful tips, practical technical information and industry news by email once every 6 weeks.
Subscribe to the Building Bulletin
Comments
LABC Response
Submitted 8 months 3 weeks ago
Best,
LABC Team
Floor area question
Submitted 1 year ago
LABC Response
Submitted 11 months 3 weeks ago
The floor areas is calculated as the internal area bounded by the external wall which should not exceed 30m2 in terms of the exemption for Building Regulations, internal walls are not included for this calculation.
Best,
LABC Team
Outbuilding
Submitted 12 months ago
LABC Response
Submitted 10 months 3 weeks ago
Unfortunately, LABC is unable to provide project specific advice and therefore for the outbuilding you describe, you would need to contact the LA to whom you made the application (for both building regulations and planning permission) to apply for the change of use for sleeping accommodation.
Best,
LABC Team
Exempt from building regs?
Submitted 7 months 1 week ago
LABC Response
Submitted 5 months 1 week ago
The detached building may be considered exempt based on the internal floor area and distance from the boundary, however there may be other elements of the proposed works, such as controlled services or fittings that may require building regulation approval. You should speak to your Local Authority Building Control Team about the works prior to carrying out any works, you can find their contact details using our postcode search function.
Best,
LABC Team
Add new comment