Construction Details
LABC Registered Construction Details are only valid for use with building work intended to follow the guidance in the following:
England
- Approved Document L1A and L2A (2013 edition incorporating amendments up to and including 2016)
- Approved Document L1B (2010 edition incorporating amendments up to and including 2018)
- Approved Document L2B (2010 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2021 edition) or any subsequent amendments.
Wales
Approved Document L1A, L1B, L2A and L2B (2014 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2022 edition) or any subsequent amendments.
E2MCPF9 STEEL LINTEL, OPEN BACK - NO CONTINUOUS BASEPLATE
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Partial Fill Insulation
Steel Lintel, Open Back
(No continuous base plate)
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE2MCPF8 STEEL LINTEL, OPEN BACK - NO CONTINUOUS BASEPLATE
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Partial Fill Insulation
Steel Lintel, Open Back
(No continuous base plate)
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE2MCPF7 STEEL LINTEL, OPEN BACK - NO CONTINUOUS BASEPLATE
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Partial Fill Insulation
Steel Lintel, Open Back
(No continuous base plate)
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE2MCPF6 Independent Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Partial Fill Insulation
Independent Lintel
Proprietary PVC-U Cavity Closer
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE2MCPF5 Independent Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Partial Fill Insulation
Independent Lintel
Proprietary PVC-U Cavity Closer
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE2MCPF4 Independent Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Partial Fill Insulation
Independent Lintel
Proprietary PVC-U Cavity Closer
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE1MCPF6 Steel Lintel, Perforated Base Plate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Partial Fill Insulation
Steel Lintel with Perforated Baseplate
(Insulated Soffit)
This LABC Registered Construction Detail is only valid for use with building work intended...
View DetailsE1MCPF5 Steel Lintel, Perforated Base Plate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Partial Fill Insulation
Steel Lintel with Perforated Baseplate
(Insulated Soffit)
This LABC Registered Construction Detail is only valid for use with building work intended...
View DetailsE1MCPF4 Steel Lintel, Perforated Base Plate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Partial Fill Insulation
Steel Lintel with Perforated Baseplate
(Insulated Soffit)
This LABC Registered Construction Detail is only valid for use with building work intended...
View Details