Construction Details
LABC Registered Construction Details are only valid for use with building work intended to follow the guidance in the following:
England
- Approved Document L1A and L2A (2013 edition incorporating amendments up to and including 2016)
- Approved Document L1B (2010 edition incorporating amendments up to and including 2018)
- Approved Document L2B (2010 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2021 edition) or any subsequent amendments.
Wales
Approved Document L1A, L1B, L2A and L2B (2014 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2022 edition) or any subsequent amendments.
E6SMEW1 Intermediate Timber Floor within a Dwelling
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.022 W/mK)
Timber Floor Joists Between Floor built in or on hangers
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in...
View DetailsE5SMEW32 Concrete Ground Bearing Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.038 W/mK)
In Situ Ground Bearing Concrete Floor
150mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE5SMEW31 Concrete Ground Bearing Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.022 W/mK)
In Situ Ground Bearing Concrete Floor
150mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE5SMEW26 Concrete Ground Bearing Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.038 W/mK)
In Situ Ground Bearing Concrete Floor
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE5SMEW25 Concrete Ground Bearing Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.022 W/mK)
In Situ Ground Bearing Concrete Floor
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE5SMEW20 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Cast In-Situ Suspended Slab
150mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW19 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.022 W/mK)
150mm Cast In-Situ Suspended Slab
150mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW14 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Cast In-Situ Suspended Slab
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW13 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.022 W/mK)
150mm Cast In-Situ Suspended Slab
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW2 Suspended Beam and Block Floor, Insulation above Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Beam and Aircrete Block Infill
100mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered Construction Detail is only valid for use with building work...
View Details