Construction Details
LABC Registered Construction Details are only valid for use with building work intended to follow the guidance in the following:
England
- Approved Document L1A and L2A (2013 edition incorporating amendments up to and including 2016)
- Approved Document L1B (2010 edition incorporating amendments up to and including 2018)
- Approved Document L2B (2010 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2021 edition) or any subsequent amendments.
Wales
Approved Document L1A, L1B, L2A and L2B (2014 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2022 edition) or any subsequent amendments.
E5SMEW18 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.19 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Cast In-Situ Suspended Slab
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW17 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.19 W/mK)
Render & Insulation (λ = 0.022 W/mK)
150mm Cast In-Situ Suspended Slab
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW16 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.15 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Cast In-Situ Suspended Slab
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW15 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.15 W/mK)
Render & Insulation (λ = 0.022 W/mK)
150mm Cast In-Situ Suspended Slab
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW14 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Cast In-Situ Suspended Slab
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW13 Suspended In-Situ Concrete Floor, Insulation below Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.11 W/mK)
Render & Insulation (λ = 0.022 W/mK)
150mm Cast In-Situ Suspended Slab
100mm Insulation Below Slab (0.022W/mK)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE5SMEW12 Suspended Beam and Block Floor, Insulation above Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.19 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Beam and Aircrete Block Infill
150mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered Construction Detail is only valid for use with building work...
View DetailsE5SMEW11 Suspended Beam and Block Floor, Insulation above Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.19 W/mK)
Render & Insulation (λ = 0.022 W/mK)
150mm Beam and Aircrete Block Infill
150mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered Construction Detail is only valid for use with building work...
View DetailsE5SMEW6 Suspended Beam and Block Floor, Insulation above Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.19 W/mK)
Render & Insulation (λ = 0.038 W/mK)
150mm Beam and Aircrete Block Infill
100mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered Construction Detail is only valid for use with building work...
View DetailsE5SMEW5 Suspended Beam and Block Floor, Insulation above Slab
Build Up
Solid External Masonry Wall
215mm Aircrete Solid Wall (λ = 0.19 W/mK)
Render & Insulation (λ = 0.022 W/mK)
150mm Beam and Aircrete Block Infill
100mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered Construction Detail is only valid for use with building work...
View Details