Construction Details
LABC Registered Construction Details are only valid for use with building work intended to follow the guidance in the following:
England
- Approved Document L1A and L2A (2013 edition incorporating amendments up to and including 2016)
- Approved Document L1B (2010 edition incorporating amendments up to and including 2018)
- Approved Document L2B (2010 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2021 edition) or any subsequent amendments.
Wales
Approved Document L1A, L1B, L2A and L2B (2014 edition incorporating amendments up to and including 2016)
NOTE: LABC Registered Construction Details should not be used for Approved Document L Volume 1 and 2 (2022 edition) or any subsequent amendments.
E6MCPF3 Intermediate floor within a dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE6MCPF2 Intermediate floor within a dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK
Partial Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
This LABC Registered Construction Detail is only valid for use with building work intended...
View DetailsE6MCPF1 Intermediate floor within a dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block Inner Leaf λ ≤ 0.28 W/mK
Partial Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
This LABC Registered Construction Detail is only valid for use with building work...
View DetailsE6MCFF3 Intermediate Floor Within a Dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
This LABC Registered Construction Detail is only valid for use with building work intended to follow the...
View DetailsE6MCFF2 Intermediate Floor Within a Dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block λ ≤ 0.60 W/mK
Full Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
This LABC Registered Construction Detail is only valid for use with building work intended to follow the...
View DetailsE6MCFF1 Intermediate Floor Within a Dwelling
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block λ ≤ 0.28 W/mK
Full Fill Insulation
Intermediate Timber Floor Within Dwelling
Timber Joist
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE7MCPF3 Concrete intermediate floor between dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block Inner Leaf λ ≤1.33 W/mK
Partial Fill Insulation
Precast Concrete Floor Between Dwellings
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance...
View DetailsE7MCPF2 Concrete intermediate floor between dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Lightweight Concrete Block Inner Leaf λ ≤ 0.60 W/mK
Partial Fill Insulation
Precast Concrete Floor Between Dwellings
This LABC Registered Construction Detail is only valid for use with building work intended to follow the...
View DetailsE7MCPF1 Concrete intermediate floor between dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Ultra Lightweight Concrete Block Inner Leaf λ ≤ 0.28 W/mK
Partial Fill Insulation
Precast Concrete Floor Between Dwellings
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE7MCFF3 Concrete intermediate floor between dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Dense Concrete Block λ ≤1.33 W/mK
Full Fill Insulation
Precast Concrete Floor Between Dwellings
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the...
View Details