E3MCFF4 Sill
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Window Sill
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England
...
View DetailsE2MCFF9 Steel Lintel, Open Back - No Continuous Baseplate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
Steel Lintel, Open Back
(No continuous base plate)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE2MCFF8 Steel Lintel, Open Back - No Continuous Baseplate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Steel Lintel, Open Back
(No continuous base plate)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE2MCFF7 Steel Lintel, Open Back - No Continuous Baseplate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Steel Lintel, Open Back
(No continuous base plate)
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE2MCFF6 Independent Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
Independent Lintel
Proprietary PVC-U Cavity Closer
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE2MCFF5 Independent Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Independent Lintel
Proprietary PVC-U Cavity Closer
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE2MCFF4 Independent Lintel
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Independent Lintel
Proprietary PVC-U Cavity Closer
This LABC Registered Construction Detail is only valid for use with building work intended to follow...
View DetailsE1MCFF6 Steel Lintel, Perforated Base Plate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
Steel Lintel with Perforated Baseplate
(Insulated Soffit)
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE1MCFF5 Steel Lintel, Perforated Base Plate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Steel Lintel with Perforated Baseplate
(Insulated Soffit)
This LABC Registered Construction Detail is only valid for use with building work intended to...
View DetailsE1MCFF4 Steel Lintel, Perforated Base Plate
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Steel Lintel with Perforated Baseplate
(Insulated Soffit)
This LABC Registered Construction Detail is only valid for use with building work intended to...