E18MCFF9 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
This LABC Registered Construction...
View DetailsE18MCFF8 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
This LABC Registered Construction...
View DetailsE18MCFF7 Party Wall Between Dwellings
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
2 x 100mm Aircrete Block (0.15W/m²K) Party (Separating) Wall
100mm cavity fully filled with insulation (0.044W/mK)
This LABC Registered Construction...
View DetailsE17MCFF6 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
Inverted Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
Engla...
View DetailsE17MCFF5 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Inverted Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
Engla...
View DetailsE17MCFF4 Inverted Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Inverted Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
Engla...
View DetailsE16MCFF6 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
Normal Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England...
View DetailsE16MCFF5 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
Full Fill Insulation
Normal Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England...
View DetailsE16MCFF4 Normal Corner
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.11 W/mK)
Full Fill Insulation
Normal Corner
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England...
View DetailsE13MCFF6 Pitched Roof, Gable, Insulation At Rafter Level
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
100mm Aircrete Block Inner Leaf (λ = 0.19 W/mK)
Full Fill Insulation
Pitched Roof Gable
150mm insulation (0.044W/mK) between rafters
50mm insulation (0.022W/mK) beneath rafters
Unventilated Rafter Void
This LABC...
View Details