E5MCPF20 Suspended Beam And Block Floor, Insulation Above Slab
Build Up
External Masonry Cavity Wall
Masonry Outer Leaf (λ = 0.77)
Partial Fill Insulation
100mm Aircrete Block Inner Leaf (λ = 0.15 W/mK)
150mm Beam and Aircrete Block Infill
150mm Insulation Above Slab (0.022W/mK)
75mm Screed
This LABC Registered Construction Detail is only valid for use with building work intended to follow the guidance in the following:
England
- Approved Document L1A and L2A (2013 edition incorporating amendments up to and including 2016)
- Approved Document L1B (2010 edition incorporating amendments up to and including 2018)
- Approved Document L2B (2010 edition incorporating amendments up to and including 2016)
NOTE: This LABC Registered Construction Detail should not be used for Approved Document L Volume 1 and 2 (2021 edition) or any subsequent amendments.
Wales
- Approved Document L1A, L1B, L2A and L2B (2014 edition incorporating amendments up to and including 2016)
NOTE: This LABC Registered Construction Detail should not be used for Approved Document L Volume 1 and 2 (2022 edition) or any subsequent amendments.
Architect downloads
e5mcpf20_cad_file.dwg74.92 KB
Registered Detail certificates
e5mcpf20_certificate.pdf779.9 KB
rcd_worksheet_220.pdf340.6 KB